High Temperature Cable insulating layer, the first layer insulation material for alkali-free glass fiber woven layer, the second choose 0.15 mm thick insulation, overlapping rate was 50%, heat-resistant up to 1000 ℃ of composite mica tape around the package layer, third layer insulation materials for alkali-free glass fiber woven, described in the composite insulation outside wrapped in a layer of protective layer, the protective coating materials for organic silicon paint. High Temperature Cable
With efficient manufacturing capabilities, we ensure that the quality and supply capabilities of our temperature cable, high temperature wires, dimplex tubular heater 80w can always meet the dynamic requirements of the market. We have established a perfect marketing system that integrates sales, customer service, market research, analysis and decision making. We deepened and improved the development system and management system of the company in order to ensure the implementation of the strategy. In the process of improving the mode of production and operation, enterprises must reinforce the system construction, standardize the operation behavior and promote the transformation of the social relation network of production and operation. Welcome to inquire!
High Temperature Cable
Abstract: the utility model discloses a kind of high temperature resistance of pure nickel wire, including the conductor and an insulator, conductor described in 14 root 0.3 mm pure nickel wire twisted and become, described the conductor outside wrapped composed of multilayer insulation composite insulating layer, the first layer insulation material for alkali-free glass fiber woven layer, the second choose 0.15 mm thick insulation, overlapping rate was 50%, heat-resistant up to 1000 ℃ of composite mica tape around the package layer, third layer insulation materials for alkali-free glass fiber woven, described in the composite insulation outside wrapped in a layer of protective layer, the protective coating materials for organic silicon paint.
High Temperature Cable
Principal right requirements: a kind of high temperature resistance of pure nickel wire, including the conductor and an insulator, whose character is: the conductor described by 14 root 0.3 mm pure nickel wire twisted and become, described the conductor outside wrapped composed of multilayer insulation composite insulating layer, the first layer insulation material for alkali-free glass fiber woven layer, the second choose 0.15 mm thick insulation, overlapping rate was 50%, heat-resistant up to 1000 ℃ of composite mica tape around the package layer, third layer insulation materials for alkali-free glass fiber woven, described in the composite insulation outside wrapped in a layer of protective layer, the protective coating materials for organic silicon paint.
Mica-Glass insulated high temperature cable for induction heater
Technical data:
1. Product standard: gb1266.6-90 q1321281kla02-2009
2. Refractory wire YW500(350℃~800℃) does not burn
3. Rated temperature:500℃~ 800℃
4. Rated voltage:750 v
5. Conductor adopts naked copper, nickel-plated copper or pure nickel wire, single wire or stranded wire 0.5~25mm2.
6. The insulation material is made of natural mica tape and glass fiber.
Imported high temperature mica rubber vacuum high temperature sintering composition.
The colors are red, blue, white, yellow, green, brown and black
Type and name:
GN-500-01-Pure nickel wire fire resistant electric wire and cable 1000℃
GN-500-02-Nickel plating copper wire fire resistant electric wire and cable 800℃
GN-500-03-Oxygen free cooper wire fire resistant electric wire and cable 500℃
GN-500-04-Zinc plated copper wire fire resistant electric wire and cable 300℃
Product charanteristic
Rate voltage:Below 750W
Size:National standard 0.5/0.75//1.5/2/2.5/3/3.5/4/6/10/16/20/25...
Core material:Anaerobic pure copper wire
Insulation layer:fiberglass weave+mica tape surround+fiberglass weave
Installation conditions:Fixed installation
Rated temperature:300-1000℃
The length of per roll:100meters
It’s bendable,flame resistance and non-poisonous
Nominal | Conductor | Insulation | Outside diameter | DCR conductor | Packing length |
Mm*2 | mm | mm | mm | mm | m |
0.5 | 7*0.3 | 0.5 | 2.3±0.3 | 40.8 | 200 |
0.75 | 11*0.3 | 0.5 | 2.5±0.3 | 24.3 | 200 |
1 | 14*0.3 | 0.5 | 2.6±0.3 | 20 | 200 |
1.5 | 21*0.3 | 0.5 | 2.9±0.3 | 12.6 | 100 |
2 | 28*0.3 | 0.6 | 3.3±0.5 | 9.84 | 100 |
2.5 | 35*0.3 | 0.6 | 3.6±0.5 | 7.37 | 100 |
4 | 56*0.3 | 0.8 | 4.7±0.5 | 4.83 | 100 |
6 | 84*0.3 | 0.8 | 5.5±0.5 | 3.26 | 100 |
10 | 84*0.4 | 0.8 | 6.6±0.5 | 1.8 | 100 |
16 | 228*0.3 | 0.8 | 7.8±0.5 | 1.31 | 100 |
126*0.4 | 0.8 | 7.8±0.5 | 1.31 | 100 | |
25 | 196*0.4 | 0.8 | 9.5±0.5 | 0.758 | 100 |
361*0.3 | 0.8 | 9.5±0.5 | 0.758 | 100 | |
35 | 394*0.3 | 1 | 11.2±1.0 | 0.548 | 100 |
50 | 396*0.4 | 1.2 | 13.2±1.0 | 0.384 | 100 |
703*0.3 | 1.2 | 13.2±1.0 | 0.384 | 100 |
Delivery & Enquiries:
Most items are available for delivery in 3 to 7 working days. However, Ts heater do offer additional emergency services for customers who are in a breakdown situation. This includes a 48hr services on Mica products, Cartridge Heaters and Ceramic Knuckle Heaters. For all enquires please contact a member of our sales team who will be happy to assist.
We insist on proceeding from reality, studying the market trend down-to-earth, and focusing on the quality of UL44 Aluminum Rhw-2/Rhh/Use-2 Building Wire. Success is the unremitting pursuit of every one of our employees, and our company is developing and growing in the process of pursuing success after success. Our company strives for survival by quality and development by reputation. The requirements of users are our goal, and the satisfaction of users is our wish. We will, as always, work with you to create brilliance together, and we are sincerely waiting for your visit.